TLX RF & Microwave Laminate: Typical Values


TLX-9 TYPICAL VALUES
PROPERTY TEST METHOD UNITS VALUE UNITS VALUE
Dielectric Constant
@ 10 GHz
IPC-TM-650 2.5.5 2.50 2.50
Dissipation Factor
@ 10 GHz
IPC-TM-650 2.5.5 0.0019 0.0019
Moisture Absorption IPC-TM-650 2.6.2.1 % <0.02 % <0.02
Dielectric Breakdown IPC-TM-650 2.5.6 kV >60 kV >60
Volume Resistivity IPC-TM-650 2.5.17.1 Mohm/cm 107 Mohm/cm 107
Surface Resistivity IPC-TM-650 2.5.17.1 Mohm 107 Mohm 107
Arc Resistance IPC-TM-650 2.5.1 Seconds >180 Seconds >180
Flexural Strength Lengthwise IPC-TM-650 2.4.4 psi >23,000 N/mm² >159
Flexural Strength Crosswise IPC-TM-650 2.4.4 psi >19,000 N/mm² >131
Peel Strength IPC-TM-650 2.4.8 lbs./ inch 12.0 N/mm 2.1
Thermal Conductivity ASTM C 177
(guarded hotplate)
W/mK 0.19 W/mK 0.19
x-y CTE TMA ppm/°C 9 - 12 ppm/°C 9 - 12
z CTE TMA ppm/°C 130-145 ppm/°C 130-145
UL-94 Flammability Rating UL-94 V-0 V-0