TLY-5 RF & Microwave Laminate: Typical Values


TLY-5 Typical Values
PROPERTY TEST METHOD UNITS VALUE UNITS VALUE
Dielectric Constant
@ 10 GHz
IPC TM 650 2.5.5 2.20 2.20
Dissipation Factor
@ 10 GHz
IPC TM 650 2.5.5 0.0009 0.0009
Moisture Absorption IPC TM 650 2.6.2.1 % <0.02 % <0.02
Dielectric Breakdown IPC-TM-650 2.5.6 kV >60 kV >60
Volume Resistivity IPC-TM-650 2.5.17.1 Mohm/cm 107 Mohm/cm 107
Surface Resistivity IPC-TM-650 2.5.17.1 Mohm 107 Mohm 107
Arc Resistance IPC-TM-650 2.5.1 Seconds >180 Seconds >180
Flexural Strength Lengthwise IPC-TM-650 2.4.4 psi >12,000 N/mm² >83
Flexural Strength Crosswise IPC-TM-650 2.4.4 psi >10,000 N/mm² >69
Peel Strength IPC-TM-650 2.4.8 lbs./ inch 12.0 N/mm 2.1
Thermal Conductivity ASTM C 177
(guarded hotplate)
W/m/K 0.22 W/m/K 0.22
x-y CTE TMA ppm/ºC 20 ppm/ºC 20
z CTE TMA ppm/ºC 280 ppm/ºC 280
UL-94 Flammability Rating UL-94 V-0 V-0









How to order TLY
TLY Data Sheet
Back to Products Overview