| TLC TYPICAL VALUES |
| PROPERTY |
TEST METHOD |
UNITS |
VALUE |
UNITS |
VALUE |
Tensile Strength - Warp - Fill |
|
psi |
22,000 18,000 |
N/mm² |
52 24 |
Flex Modulus - Warp - Fill |
|
psi |
490 3.4 |
N/mm² |
530 3.6 |
Flex Strength - Warp - Fill |
|
psi |
15,000 12,000 |
N/mm² |
103 83 |
| Compressive Strength |
|
kV |
24,000 |
kV |
165 |
Impact Strength - Warp - Fill |
|
ft*lbs/in |
14 13 |
N/mm² |
2.6 2.3 |
| Elongation |
|
% |
max. 0.05 |
% |
max. 0.05 |
| Water Absorption |
|
% |
max. 0.15 |
% |
max. 0.15 |
| Density |
|
g/cm³ |
2.2 |
g/cm³ |
2.2 |
| Hardness |
Rockwell M |
|
30 |
|
30 |
| Flammability |
|
|
non-flammable |
|
non-flammable |
| max. Operating Temperature |
|
°C |
260 |
°C |
260 |
|